Skip to main content

Table 2 Mean values and standard error of water potentials inducing 50% loss of conductivity (P50) estimated with a 100-cm rotor (P50 CAVI 1000) and with associated reference technique (P50 reference). n corresponds to the number of replicates for each mean value, and d corresponds to the average sample diameter

From: Measuring xylem hydraulic vulnerability for long-vessel species: an improved methodology with the flow centrifugation technique

Species

P50 CAVI 1000 (MPa)

P50 reference (MPa)

Reference method used

Liriodendron tulipifera

− 1.99 (± 0.08), n = 8, d = 10.9 mm

− 2.05 (± 0.10), n = 9, d = 6.1 mm

Cavitron

Populus nigra

− 2.12 (± 0.04), n = 8, d = 12.0 mm

− 2.21 (± 0.06), n = 7, d = 3.9 mm

Cavitron

Quercus ilex

− 7.13 (± 0.52), n = 10, d = 11.6 mm

− 7.65 (± 0.28), n = 5, d = 1.2 mm

Micro-CT

Quercus robur

− 4.73 (± 0.24), n = 8, d = 11.7 mm

− 4.16 (± 0.27), n = 3, d = 1.1 mm

Micro-CT

Pinus pinaster

− 3.37 (± 0.08), n = 8, d = 14.3 mm

− 3.38 (± 0.21), n = 6, d = 7.5 mm

Cavitron